{"data":{"id":"us-nyc/n.y.c.-admin.-code-210.52","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § 210.52","heading":"Section 210.52","body":"Section 210.52(J) – Add a new Section 210.52(J) to read as follows:\n\n(J) Outlet Requirements For Residential-Type Occupancies. In addition to the requirements set forth in (A) through (I) of this section, living rooms, bedrooms, dining rooms or similar rooms shall have at least 1 receptacle outlet installed for air conditioners. Such receptacle outlets shall be supplied by an individual branch circuit.\n\nException: For buildings with central air conditioning systems, a separate receptacle outlet shall not be required in any living room, bedroom, dining room, or other similar room served by such system.","path":["New York City Administrative Code","Title 28","Chapter 11: The New York City Electrical Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"6feb5b08262243cf435920c365e8ab24ea4d7f345a494b19a7f37814c3ec70d8","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-210.50","next":"us-nyc/n.y.c.-admin.-code-215.2"},"notice":"GroundRules: Original legal text. Not legal advice."}