{"data":{"id":"us-nyc/n.y.c.-admin.-code-27-475","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § 27-475","heading":"§ 27-475 Attached garages.","body":"Private garages attached to, or located above or below, a dwelling shall have walls, partitions, floors, and ceilings separating the garage from the dwelling, having a fire-resistance rating of at least one hour, except that such fire-resistive construction shall not be required between a dwelling and a carport when such carport is open on at least two sides. Any openings to the dwelling in required walls or partitions shall be protected with one and three-quarter inch solid core wood doors or equivalent.","path":["New York City Administrative Code","Title 27","Chapter 1: Building Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"3b2aca1d15d64f49b91220576566d7a4b7a6f169aeb51e9a6ee1655f204c87eb","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-27-474","next":"us-nyc/n.y.c.-admin.-code-27-476"},"notice":"GroundRules: Original legal text. Not legal advice."}