{"data":{"id":"us-nyc/n.y.c.-admin.-code-27-490","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § 27-490","heading":"§ 27-490 Dressing facilities.","body":"Toilet rooms, shower rooms, and indoor dressing areas shall be constructed of nonabsorbent materials with smooth-finish walls and partitions. Floors shall have a nonslip surface impervious to moisture, free of cracks or open joints, and sloped to drains. The junctions between the side walls and floors shall be coved. Individual dressing rooms or cubicles within indoor dressing areas shall be excluded from the above requirements. Cabanas and dressing rooms that are not a part of any other occupancy shall also be excluded. Toilets and showers. Toilets, lavatories, and showers, including piping, shall be provided in accordance with the requirements of subchapter sixteen of this chapter.","path":["New York City Administrative Code","Title 27","Chapter 1: Building Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"e1002cf15533b70b35df5afaf88c6e253e4e790d6ed649d3549adf9aa364269c","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-27-489","next":"us-nyc/n.y.c.-admin.-code-27-491"},"notice":"GroundRules: Original legal text. Not legal advice."}