{"data":{"id":"us-nyc/n.y.c.-admin.-code-27-595","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § 27-595","heading":"§ 27-595 Deflection limitations.","body":"The applicable provisions of the several reference standards cited in this subchapter shall apply. In addition, the total of the dead plus live load vertical deflections (including effects of creep and shrinkage) of members, supporting walls, veneered walls, or partitions constructed of or containing panels of masonry, glass, or other frangible materials shall not exceed 1/360 of the span.","path":["New York City Administrative Code","Title 27","Chapter 1: Building Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"ad63c008ac8a02481f78132652bda0f5ca4eeef2b7756c76765c6432540e5a70","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-27-594","next":"us-nyc/n.y.c.-admin.-code-27-596"},"notice":"GroundRules: Original legal text. Not legal advice."}