{"data":{"id":"us-nyc/n.y.c.-admin.-code-27-650","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § 27-650","heading":"§ 27-650 Deflection of support.","body":"The deflection of members supporting glass panels under the design wind load (measured perpendicular to the plane of the panel) shall not exceed L/175, where L is the span of the supporting member. In no case shall such deflection exceed three-quarters of an inch.","path":["New York City Administrative Code","Title 27","Chapter 1: Building Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"9c54cf2d3f0c927c422e0761f9858ccdb5d193a99bf9527aaf8e21426260cb8e","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-27-649","next":"us-nyc/n.y.c.-admin.-code-27-651"},"notice":"GroundRules: Original legal text. Not legal advice."}