{"data":{"id":"us-nyc/n.y.c.-admin.-code-27-811","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § 27-811","heading":"§ 27-811 Insulation materials.","body":"All insulations shall be of noncombustible materials. All coverings, vapor barriers and adhesives shall have a flame spread rating no higher than twenty-five and a smoke developed rating no higher than fifty. Adhesives and mastic finishes shall be tested in sufficient bulk to produce maximum burning, and shall be tested in accordance with reference standard RS 14-11.","path":["New York City Administrative Code","Title 27","Chapter 1: Building Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"d3da2ac2e9e4bb1b4d8ed2ec5091635f3a68263ab97c4070671c4882c696f881","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-27-810","next":"us-nyc/n.y.c.-admin.-code-27-812"},"notice":"GroundRules: Original legal text. Not legal advice."}