{"data":{"id":"us-nyc/n.y.c.-admin.-code-bc-1909","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § BC 1909","heading":"Section BC 1909: Structural Plain Concrete","body":"1909.1 Scope.\n\nThe design and construction of structural plain concrete, both cast-in-place and precast, shall comply with the minimum requirements of ACI 318, as modified by Section 1908 of this chapter.\n\nException: For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required footing thickness of ACI 318 is permitted to be reduced to 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm) on either side of the supported wall.","path":["New York City Administrative Code","Title 28","Chapter 7: New York City Building Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"507d67e75a2620df29fdc457e0ebb1b5172edd52b52b3bb250ae2785ebe4a9d9","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-bc-1908","next":"us-nyc/n.y.c.-admin.-code-bc-1910"},"notice":"GroundRules: Original legal text. Not legal advice."}