{"data":{"id":"us-nyc/n.y.c.-admin.-code-fc-504","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § FC 504","heading":"Section FC 504: Building and Rooftop Access","body":"504.1 Frontage space.\n\nBuildings shall be provided with a frontage space in compliance with the requirements of this chapter and the Building Code. The term \"frontage space\" shall have the meaning set forth in FC 202 for purposes of this code. For purposes of the Building Code, \"frontage space\" shall have the meaning set forth in Section 502 thereof.\n\nException: Accessory buildings or structures classified by the Building Code as a Group U occupancy.\n\n504.1.1 Main front entrance.\n\nThe main front entrance of a building is the entrance that is designed to serve as the primary means of ingress and egress to the building, and which is located on a side of the building that contains windows, emergency escape and rescue openings, outdoor building corridors or other building openings that serve to afford firefighters access to the upper floors of the building. Where a building has more than one entrance that is so designed and situated, the owner may designate one such entrance as the main front entrance of the building, provided, however, that if such entrance does not provide an appropriate location for firefighting operations, the commissioner may require that another entrance be designated the main front entrance.\n\n504.1.2 Occupancies with separate entrances.\n\nWhen a building contains more than one occupancy or is primary to a semi-attached or detached ancillary dwelling unit, as defined by Section U102 of the Building Code, and separate entrances are provided for individual occupancies, there shall be a main front entrance for each such occupancy, and a separate frontage space shall be provided for each main front entrance, except that a second frontage space is not required for a two-family Group R-3 occupancy or a dwelling unit ancillary to a one-family or two-family Group R-3 occupancy if unobstructed access, 5 feet (1524 mm) in width, is provided to the rear yard and to the main front entrance of any dwelling unit from either side of the building that is not directly accessible from the public street, fire apparatus access road, or driveway. An open accessory parking area not less than 5 feet (1524 mm) in width shall be sufficient to constitute unobstructed access to the rear yard, regardless of the presence of parked vehicles in such parking area.\n\n504.1.2.1 Detached ancillary dwelling units.\n\nA detached ancillary dwelling unit is not required to provide frontage space if access to the main front entrance of the detached ancillary dwelling unit is provided in accordance with the requirements for unobstructed access set forth in FC 504.1.2 and Table U103.8 of Appendix U of the Building Code.\n\n(L.L. 2024/127, 12/18/2024, eff. 6/16/2025)\n\n504.1.3 Building access.\n\nAn approved access walkway leading from the fire apparatus access road or driveway to the main front entrance of each occupancy or other exterior openings shall be provided when required by the commissioner.\n\n504.1.4 Frontage space obstructions.\n\nObstructions, such as planters, fences and bollards, shall not be placed in the required frontage space unless they have been approved by the Commissioner of Buildings, the Commissioner of Transportation, or the commissioner, as applicable.\n\n504.2 Maintenance of exterior doors and openings.\n\nExterior doors and openings required by this code or the construction codes, including the Building Code, \n\t\t\t\t\t\t\t\t\t\t\t\t\tshall be maintained in a manner that affords access by firefighting personnel in accordance with the requirements of this section, FC Chapter 10, and the Building Code. Exterior doors and their function shall not be eliminated without prior approval of the Department of Buildings. Exterior doors that have been rendered nonfunctional and that retain a functional door exterior appearance shall have a sign affixed to the exterior side of the door with the words THIS DOOR BLOCKED. The sign shall consist of letters having a principal stroke of not less than 0.75 inch (19.1 mm) wide and at least 6 inches (152 mm) high on a contrasting background. Required department access doors shall not be obstructed or eliminated. Exit and exit access doors shall comply with the requirements of FC Chapter 10 and the construction codes, including the Building Code. Access doors for high-piled combustible storage shall comply with the requirements of FC 3206.6.1.\n\n504.3 Stairway access to roof.\n\nStairway access to the roof shall be in accordance with FC Chapter 10 and the construction codes, including the Building Code. Such stairway shall be marked at street and floor levels with a sign indicating that the stairway continues to the roof. Where roofs are used for rooftop gardens or for other lawful purposes, stairways shall be provided as required for such occupancy classification.\n\n504.4 Rooftop access and obstructions.\n\nThe rooftops of buildings 100 feet (30 480 mm) or less in height, except rooftops with a slope exceeding 20 degrees (0.35 rad) from the horizontal, shall be designed, installed, operated and maintained in accordance with this section and in a manner that avoids or minimizes obstructions that impede firefighting operations such as vertical ventilation of heat and smoke, surveillance of rear yards and courtyards, and rooftop-aided rescues. For purposes of this section only, \"rooftop\" shall include rooftops of building setbacks, and \"obstruction\" shall mean any fixture or other item that is not readily movable by one person without the use of tools or equipment, including air conditioning systems, billboards and other signs, cellular antenna equipment, columns and girders, cooling towers, fuel oil storage tanks, generators, heating systems, planters, solar panels, ventilation system ducts, intakes and exhausts, and window cleaning equipment, but shall not include nonmetallic decking that is readily cut by standard power tools.\n\n504.4.1 Rooftop access.\n\nAccess to building rooftops shall be provided for fire operations by providing unobstructed access to the rooftop, including unobstructed passage across the building parapet, perimeter fence or other obstructions, and a safe landing. Such rooftop access shall be provided in compliance with the following required clearances:\n\n1. For each 12 linear feet (3658 mm) of building perimeter accessible from the frontage space of the building and from any other exposure accessible to fire apparatus, a minimum clearance of 6 feet (1829 mm) in width and 6 feet (1829 mm) in depth from any obstruction shall be provided at the parapet wall or other perimeter of the rooftop.\n\n2. Where such building perimeter is 24 linear feet (7315 mm) or greater, but less than 36 linear feet (10 973 mm), the required clearance openings shall be separated by a distance of not less than 12 linear feet (3658 mm).\n\n3. Where such building perimeter is 36 linear feet (10 973 mm) or greater, the required clearance openings may be contiguous, provided, however, that such contiguous openings shall not exceed 12 linear feet (3658 mm) and shall be separated from other required clearance openings by a distance of not less than 12 linear feet (3658 mm).\n\n4. Each exposure accessible by fire apparatus shall be treated separately for purposes of locating clearance openings and otherwise complying with the requirements of this provision.\n\n5. Awnings, sun control devices, solar panels or other structures affixed to an exterior building wall below the roof line shall not obstruct fire apparatus aerial ladder access to the rooftop perimeter access locations.\n\n6. Scaffolding obstructing rooftop access locations shall be designed to provide secure landings at such locations in an approved manner.\n\n7. The rooftop parapet or other perimeter railing or barrier shall be designed to facilitate the safe dismounting of a firefighter from an aerial ladder. Any such parapet, railing or barrier on a building constructed after the effective date of this section, or installed pursuant to a work permit issued by the Department of Buildings after such date, shall \n\t\t\t\t\t\t\t\t\t\t\t\t\tbe of substantial construction capable of supporting a minimum of 350 pounds (159 kg) and shall be designed with a level surface at least 5 inches in width (127 mm) so as to allow a firefighter to safely step on it, as prescribed by the department, or other approved design. Where the height of the rooftop parapet, railing or other enclosure is more than 48 inches (1219 mm), an approved landing platform and steps or ladder shall be provided to allow a firefighter to safely dismount and descend to the rooftop. Design and installation documents shall be submitted to the department for approval.\n\n8. To the maximum extent practicable, wind turbines or other equipment with moving components shall be installed at rooftop location where they do not impede access or encroach up rooftop access landings, clear path, or required clearances, but in no case shall fan blades or other moving component operate within 3 feet (914 mm) of the rooftop access required by this section, including the 9-foot (2743 mm) height above the parapet or other rooftop perimeter railing or barrier and rooftop access landings. The tips of the fan blades and the edges of other moving components shall bear reflective markings and identified by caution warning signs or other means, to ensure that persons on the rooftop are aware of the presence of such equipment.\n\n504.4.2 Rooftop access signs and markings.\n\nWhere required by the department, a sign, decal or approved marking shall be provided on the exterior wall of a building, at an approved location on a lower story, directly below the rooftop perimeter access landings, to identify the location of such rooftop access. The department may require such signs or markings when rooftop conditions not apparent from the street make rooftop access unsafe at locations other than the approved building perimeter access landings, or do not allow for access to the roof.\n\n504.4.3 Rooftop access landings.\n\nAt each rooftop perimeter access location, there shall be a safe landing area not less than 6 feet (1829 mm) in any dimension, and 9 feet (2743 mm) in height above the parapet or other rooftop perimeter railing or barrier. The access landing shall be connected to the clear path required by FC 504.4.4. The landing shall not be obstructed by a fence, except as approved. If approved, such fence shall be provided with a standard 3-foot-wide (914 mm) gate that swings inward. Such gate may be secured by a padlock and chain capable of being cut by standard bolt cutters from either side of the gate, or secured by other approved device.\n\n504.4.4 Rooftop clear path.\n\nA clear path of not less than 6 feet (1829 mm) horizontal width and 9 feet (2743 mm) in height shall be provided from the front of the building to the rear of the building; from one side of the building to the other for each 100 linear feet (30 480 mm) of rooftop width and depth such that the maximum distance between clear paths is 100 feet (30 480) mm. Such path shall comply with the following requirements:\n\n1. Such clear path shall be accessible from each rooftop perimeter access landing required pursuant to FC 504.4.3.\n\n2. Such clear path shall afford reasonable access to bulkhead doors, fire escapes, access ladders, cockloft vents, skylights, scuttles, shafts and rooftop stationary energy storage systems. Such access shall include, to the maximum extent practicable, 3-feet (914 mm) clearance on three sides of the skylight or scuttle. On buildings constructed after the effective date of this section, the clear path shall afford reasonable access, to the maximum extent practicable, to windowed areas on any side of the building that is not fire apparatus accessible.\n\n3. A conduit or pipe may cross such clear path in accordance with FC 504.4.7.\n\n4. Any lawful fence obstructing such clear path shall be provided with a standard 3-foot-wide (914 mm) gate, which may be secured by padlock or chain capable of being cut by standard bolt cutters, or secured by other approved device.\n\n5. When the main building rooftop has more than one level, a fixed ladder or other approved means shall be provided to afford access along the clear path from one roof level to the next, excluding any height differential between levels exceeding one story or 16 feet (4077 mm), and any level with a rooftop area that is less than 6 feet (1829 mm) in any dimension.\n\n6. On an \"H\"-shaped building or other building whose irregular configuration renders a single clear path inadequate to provide access to each wing of the building or other rooftop area, the commissioner may require one or more additional clear paths to provide adequate access to such rooftop areas.\n\n7. The rooftop surface serving as the clear path shall not be constructed of glass or other transparent or translucent material, nor shall it require a firefighter to walk upon any flush-mounted solar panels or other energized equipment.\n\n8. Rooftop stationary energy storage systems shall be designed and installed in accordance with FC 608 and the rules, including ensuring that the deflagration zone is not in the clear path and the exhaust system does not vent into the clear path.\n\n9. The requirements for wind turbines and other equipment with moving components set forth in FC 504.4.1(8) shall be applicable to the rooftop clear path.\n\n504.4.5 Rooftop clear path protection.\n\nAdequate protection, in the form of a securely affixed protective railing or barrier that is at least 42 inches (1067 mm) above the roof surface in height along the clear path, shall be provided for any shaft, building perimeter or elevation adjoining the clear path or rooftop perimeter access landing (except the rooftop access landing itself).\n\nException: Height differentials of 6 feet (1829 mm) or less.\n\n504.4.6 Required rooftop clearances.\n\nA minimum clearance of 6 feet (1829 mm) in all directions shall be provided from each door opening onto a rooftop from a dwelling unit, stairway, bulkhead, or other occupied space or means of egress, as measured from the door hinge. A minimum clearance of 3 feet (914 mm) in all directions shall be provided from any fire escape or rooftop access ladder, as measured from each side of the ladder or landing.\n\n504.4.7 Rooftop conduits and piping.\n\nTo the maximum extent practicable, conduits, including cable trays, and piping, shall be installed at rooftop locations where they do not obstruct rooftop access landings, clear path or required clearances. If it is impracticable to avoid these areas, conduits and piping shall be designed and installed to facilitate access and minimize tripping hazards. Steps or ramps (or platforms with steps, ramps or ladders) shall be provided that are constructed of noncombustible material, equipped with railings, and designed to allow any conduit or piping installations that exceed 1 foot (305 mm) in height above the roof surface, or more than 24 inches (610 mm) in width, to be readily traversed. Steps, ramps, platforms and ladders shall not be placed in areas or in a manner that would obstruct any door or means of egress. All conduits and piping installations shall be color-coded with continuous, durable and weatherproof reflective or luminescent markings as follows, and for conduit and piping installed after July 1, 2014, shall be continuously labeled in an approved manner to indicate its contents:\n\n1. High voltage wiring – Red.\n\n2. Low voltage wiring – Orange.\n\n3. Natural gas piping – Yellow.\n\n4. Other compressed gas piping – Yellow, labeled at regular intervals with the type of gas.\n\n5. Fuel oil piping – Yellow with black stripes.\n\n504.4.8 Rooftop access underneath cantilevered or overhead buildings.\n\nWhere a building is constructed directly above another building, including a building cantilevered over another building, a vertical clearance from the rooftop of the building below shall be provided for firefighting operations in accordance with the following requirements. Design and installation documents documenting compliance with this section, including the fire analysis filed with the Department of Buildings, shall be submitted for Fire Department review and approval. Such vertical clearance:\n\n1. shall be at least 12 feet (3658 mm); and\n\n2. shall be at least 9 feet (2743 mm) above the highest building feature on the rooftop when the building feature is 25 feet (7620 mm) or less from the closest exterior surface of the building constructed above; but\n\n3. shall not apply to rooftop areas above which a noncombustible screen wall or other similar structure has been constructed for purposes of zoning compliance, provided that such structure extends below the cantilever from the side wall of the new building facing a street for a width not to exceed 8 feet (2438 mm) and a depth not to exceed 12 feet (3658 mm).\n\n504.4.9 Group R-3 occupancies with shallow-pitched roofs.\n\nA Group R-3 occupancy that is primarily a building with a roof pitch of less than 9.5 degrees shall comply with FC 504.4, notwithstanding the presence of a pitched roof element such as a mansard or a penthouse with a pitched roof. A Group R-3 occupancy with a roof pitch of 9.5 degrees or more shall comply with FC 512.3, not FC 504.4.\n\n504.4.10 Rooftop telecommunications installations.\n\nTelecommunications installations on building rooftops, including cellular antenna installations, shall additionally comply with the following requirements:\n\n1. Transmitting antennas shall be identified by affixing to the antenna, the antenna mounting, or a conspicuous location near the antenna, continuous, durable and weatherproof reflective or luminescent markings and not less than 3-inch (76-mm) lettering that reads, \"TRANSMITTER.\" If the antenna is enclosed or screened, such marking shall be placed on the exterior of the enclosure or screening.\n\n2. A durable sign shall be conspicuously posted near the main building electrical panel, on the side of the bulkhead or rooftop hatch, and on or near any equipment closet, roof base station or similar telecommunications antenna installation, identifying the owner of the installation, providing a 24-hour/7-day per week telephone number by which such owner can be contacted, and identifying the installation, including antennas and other powered equipment associated with the installation, by number or other unique designation.\n\n3. Transmitting antennas and other rooftop installations subject to radio frequency exposure limits, as set forth in the regulations of the Federal Communications Commission, shall be installed in a manner that complies with the applicable exposure limits, including those applicable to rooftop access, landing, clear path and clearance areas and other rooftop areas to which the general population has uncontrolled access. Certification of compliance, in an approved format, by a qualified person trained and knowledgeable in the measurement of Federal Communications Commission radio frequency exposure limits shall be submitted to the department with rooftop access applications and upon request in connection with rooftop access inspections.\n\n504.4.11 Rooftop gardens.\n\nRooftop gardens and landscaping, including living walls, shall be designed, installed, operated and maintained in compliance with the requirements of the construction codes, including the Building Code and this section.\n\n504.4.11.1 Perimeter and clear path access.\n\nRooftop gardens and landscaping shall not obstruct any rooftop area access to which is required pursuant to this section, including rooftop perimeter access and landings, clear path and clearances.\n\n504.4.11.2 Landscaped rooftops.\n\nRooftop access landings, clear paths and other areas access to which is required pursuant to FC 504.3 and 504.4.4 may be landscaped in compliance with the following requirements:\n\n1. The earth or other landscaping material in such areas shall be securely contained and compacted in such a manner as to ensure a stable, continuous surface with a slope not exceeding the slope of the rooftop.\n\n2. Vegetation in such areas shall be limited to grass or other plants that do not exceed 12 inches (305 mm) in height and do not constitute a tripping hazard or pitfall.\n\n504.4.11.3 Maintenance and water supply.\n\nRooftop gardens and landscaping shall be maintained and provided with a water supply in accordance with FC 318. Equipment used for the maintenance of rooftop gardens and landscaping shall be stored in accordance with FC 318.\n\n504.4.12 Rooftop solar installations.\n\nRooftop solar installations shall be designed, installed, operated and maintained in accordance with FC 512.\n\n504.4.13 Maintenance of rooftop building features.\n\nRooftop installations shall not obstruct the function, use or accessibility of any rooftop building features, including those listed in FC 504.4.4(2). Such rooftop building features shall be maintained in good working order to facilitate firefighting operations.\n\n504.5 Rooftop access on buildings more than 100 feet in height.\n\nTo the maximum extent practicable, a clear path complying with FC 504.4.4 shall be provided on all buildings more than 100 feet (30 480 mm) in height constructed after the effective date of this section from the bulkhead or other point of rooftop access to the rooftop perimeter on any side of the building that has windows.","path":["New York City Administrative Code","Title 29","Chapter 2: New York City Fire Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"2e04152cb63ee10d2938327965bc8c043917380b3c29e94b01923870e47de744","source_id":"us-nyc","stale":true,"prev":"us-nyc/n.y.c.-admin.-code-fc-503","next":"us-nyc/n.y.c.-admin.-code-fc-505"},"notice":"GroundRules: Original legal text. Not legal advice."}