{"data":{"id":"us-nyc/n.y.c.-admin.-code-fc-6503","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § FC 6503","heading":"Section FC 6503: General Requirements","body":"6503.1 Displays.\n\nFinished pyroxylin plastic products displayed in areas to which the public has access shall be placed on tables not more than 3 feet (914 mm) wide and 10 feet (3048 mm) long. Tables shall be spaced at least 3 feet (914 mm) apart. Where articles are displayed on counters, they shall be arranged in a like manner.\n\n6503.2 Space under tables.\n\nSpaces underneath tables on which finished pyroxylin plastic products are displayed shall be kept free from storage of any kind and accumulation of rubbish or other combustible waste or any other combustible material.\n\n6503.3 Location.\n\nTables on which finished pyroxylin plastic products are displayed shall be so located that in the event of a fire at the table, the table will not interfere with any means of egress.\n\n6503.4 Lighting.\n\nLighting shall not be located directly above pyroxylin plastics, unless provided with a suitable guard to prevent heated particles or broken bulb elements from falling.","path":["New York City Administrative Code","Title 29","Chapter 2: New York City Fire Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"a6deecc81119447b75bffc7e14f5ad9a5f152d28e8e97c381f79f2a3f38bd57c","source_id":"us-nyc","stale":true,"prev":"us-nyc/n.y.c.-admin.-code-fc-6502","next":"us-nyc/n.y.c.-admin.-code-fc-6504"},"notice":"GroundRules: Original legal text. Not legal advice."}