{"data":{"id":"us-nyc/n.y.c.-admin.-code-fc-806","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § FC 806","heading":"Section FC 806: Interior Finishes","body":"806.1 General.\n\nThe quantity and type of interior finishes shall comply with the requirements of Chapter 8 of the Building Code.\n\n806.2 Foam plastic signs.\n\nFoam plastic signs that are not interior finishes shall have a maximum heat release rate of 150 kW when tested in accordance with UL 1975, or when tested in accordance with NFPA 289 using the 20 kW ignition source.","path":["New York City Administrative Code","Title 29","Chapter 2: New York City Fire Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"ce9530f018b00f580cc1d9df219bdaf17717194030492fefce21ae06c9e82ed7","source_id":"us-nyc","stale":true,"prev":"us-nyc/n.y.c.-admin.-code-fc-805","next":"us-nyc/n.y.c.-admin.-code-fc-901"},"notice":"GroundRules: Original legal text. Not legal advice."}