{"data":{"id":"us-nyc/n.y.c.-admin.-code-fgc-605","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § FGC 605","heading":"Section FGC 605: Vented Gas Fireplace Heaters","body":"605.1 General.\n\nVented gas fireplace heaters shall be installed in accordance with the manufacturer's instructions, shall be tested in accordance with ANSI Z21.88/CSA 2.33 and shall be designed and equipped as specified in Section 602.2. The installation of unvented gas fired space heaters, gas stoves, gas logs, gas fireplaces and gas fireplace inserts is prohibited.\n\n605.2 Separate flues.\n\nSeparate flues shall be provided for every fireplace and fireplace stove.\n\n605.3 Combustion Air Supply.\n\nThe requirements of the New York City Energy Conservation Code concerning combustion air supply shall be followed.","path":["New York City Administrative Code","Title 28","Chapter 9: New York City Fuel Gas Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"9db21664ff58bf2f07e72bb8d3e01a1de8dc445f1af252e40eeeecff2ef3f38c","source_id":"us-nyc","stale":true,"prev":"us-nyc/n.y.c.-admin.-code-fgc-604","next":"us-nyc/n.y.c.-admin.-code-fgc-606"},"notice":"GroundRules: Original legal text. Not legal advice."}