{"data":{"id":"us-nyc/n.y.c.-admin.-code-pc-1103","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § PC 1103","heading":"Section PC 1103: Traps","body":"1103.1 Main trap.\n\nLeaders and storm drains connected to a combined sewer shall be trapped. Individual storm water traps shall be installed on the storm water drain branch serving each conductor, or a single trap shall be installed in the main storm drain just before its connection with the combined building sewer or the public sewer. A hooded catch basin located within the property line shall be the equivalent of a building-house trap for the connection to a public sewer.\n\n1103.2 Material.\n\nStorm water traps shall be of an approved material in accordance with \n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\tTable 1102.7\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t.\n\n1103.3 Size.\n\nTraps for individual conductors shall be the same size as the horizontal drain to which they are connected.\n\n1103.4 Cleanout.\n\nAn accessible cleanout shall be installed on the building side of the trap.","path":["New York City Administrative Code","Title 28","Chapter 6: New York City Plumbing Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"68edc259618a73a467488f1d4b9c5e92a67f778d4137e5d65f2c15b541cab15a","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-pc-1102","next":"us-nyc/n.y.c.-admin.-code-pc-1104"},"notice":"GroundRules: Original legal text. Not legal advice."}