{"data":{"id":"us-nyc/n.y.c.-admin.-code-pc-413","jurisdiction":"us-nyc","citation":"N.Y.C. Admin. Code § PC 413","heading":"Section PC 413: Food Waste Disposer Units","body":"413.1 Approval.\n\nDomestic food waste disposers shall conform to ASSE 1008 and shall be listed and labeled in accordance with UL 430. Food waste disposers shall not increase the drainage fixture unit load on the sanitary drainage system. Food waste disposers shall be permitted only within dwelling units.\n\n413.2 Domestic food waste disposer waste outlets.\n\nThe outlets of domestic food waste disposers shall be connected to a drain of not less than 2 inches (51 mm) in diameter.\n\n413.3 Commercial food waste disposer units.\n\nCommercial food waste disposers shall be prohibited unless approved for use by the Department of Environmental Protection.\n\n413.4 Water supply required.\n\nFood waste disposers shall be provided with a supply of cold water.","path":["New York City Administrative Code","Title 28","Chapter 6: New York City Plumbing Code"],"source_url":"https://files.amlegal.com/pdffiles/NewYorkCity/Admin/XML.zip","current_through":"Local Law 2026/135 (enacted August 31, 2026)","vintage":"","retrieved_at":"2026-09-06T02:48:57Z","sha256":"68cf225d856a88e89bf98caa30ddbf84ff90210f3b708127ef67898ab72119a9","source_id":"us-nyc","stale":false,"prev":"us-nyc/n.y.c.-admin.-code-pc-412","next":"us-nyc/n.y.c.-admin.-code-pc-414"},"notice":"GroundRules: Original legal text. Not legal advice."}