{"data":{"id":"us-va/17vac15-50-100","jurisdiction":"us-va","citation":"17VAC15-50-100","heading":"Certification","body":"Certification for archival quality processing shall be based upon the methylene blue test analysis. Processed microfilm must have an optimum concentration of greater than zero but shall not exceed .014 g/m2 in a clear film area. Film processed in-house shall be tested and certified once every two weeks or as deemed necessary by the Imaging Services Branch, The Library of Virginia. Processing services performed off-site shall include provisions requiring that the methylene blue test shall be performed once every 24 hours.","path":["Title 17. Libraries And Cultural Resources","Agency 15. Library of Virginia (Library Board)","Chapter 50. Standards for Computer Output Microfilm (Com) for Public Records","Part VI. Processing"],"source_url":"https://law.lis.virginia.gov/admincode/title17/agency15/chapter50/section100/","current_through":"2026 Regular Session (effective July 1, 2026)","vintage":"","retrieved_at":"2026-09-14T04:52:16Z","sha256":"fb753d3e29bbec9cfa51d00805a12ab8eccaff5c662ffd640223d160ff29398e","source_id":"us-va-vac","stale":false,"prev":"us-va/17vac15-50-90","next":"us-va/17vac15-50-110"},"notice":"GroundRules: Original legal text. Not legal advice."}