{"data":{"id":"us-va/4vac25-40-3680","jurisdiction":"us-va","citation":"4VAC25-40-3680","heading":"Design of shelter holes","body":"Shelter holes shall be at least four feet wide; marked conspicuously with lights, reflective signs, reflective tape, reflectors or luminous paint; provide a minimum of 40 inches clearance from the farthest projection of moving equipment; and shall not be used for storage of timber, tools, or other materials unless a 40-inch clearance is maintained.","path":["Title 4. Conservation And Natural Resources","Agency 25. Department of Energy","Chapter 40. Safety and Health Regulations for Mineral Mining","Part XV. Safety and Health Regulations—Underground Only","Article 6. Loading, Hauling, and Dumping"],"source_url":"https://law.lis.virginia.gov/admincode/title4/agency25/chapter40/section3680/","current_through":"2026 Regular Session (effective July 1, 2026)","vintage":"","retrieved_at":"2026-09-14T04:46:05Z","sha256":"335f4de530985b29473df53b8e6847b137529e98ce0bc92f697a6981d2c8b76b","source_id":"us-va-vac","stale":false,"prev":"us-va/4vac25-40-3670","next":"us-va/4vac25-40-3690"},"notice":"GroundRules: Original legal text. Not legal advice."}