{"data":{"id":"us/10-cfr-36.37","jurisdiction":"us","citation":"10 CFR 36.37","heading":"Power failures.","body":"(a) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources must automatically return to the shielded position.\n(b) The lock on the door of the radiation room of a panoramic irradiator may not be deactivated by a power failure.\n(c) During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.","path":["Title 10—Energy","CHAPTER I—NUCLEAR REGULATORY COMMISSION","PART 36—LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS","Subpart C—Design and Performance Requirements for Irradiators"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-10.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:24:09Z","sha256":"fc8902a04ab0fa4767437d0aaa8f3c95d8a85c662ea3336381a1bc91119dd8eb","source_id":"us-cfr","stale":true,"prev":"us/10-cfr-36.35","next":"us/10-cfr-36.39"},"notice":"GroundRules: Original legal text. Not legal advice."}