{"data":{"id":"us/14-cfr-25.867","jurisdiction":"us","citation":"14 CFR 25.867","heading":"Fire protection: other components.","body":"(a) Surfaces to the rear of the nacelles, within one nacelle diameter of the nacelle centerline, must be at least fire-resistant.\n(b) Paragraph (a) of this section does not apply to tail surfaces to the rear of the nacelles that could not be readily affected by heat, flames, or sparks coming from a designated fire zone or engine compartment of any nacelle.","path":["Title 14—Aeronautics and Space","CHAPTER I—FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION","SUBCHAPTER C—AIRCRAFT","PART 25—AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES","Subpart D—Design and Construction"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-14.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:24:20Z","sha256":"1f9826f2d5e3d969a2175262dde957a32b0bb5ba0f89aafb8eb50124984d8e66","source_id":"us-cfr","stale":true,"prev":"us/14-cfr-25.865","next":"us/14-cfr-25.869"},"notice":"GroundRules: Original legal text. Not legal advice."}