{"data":{"id":"us/14-cfr-27.1393","jurisdiction":"us","citation":"14 CFR 27.1393","heading":"Minimum intensities in any vertical plane of forward and rear position lights.","body":"Each position light intensity must equal or exceed the applicable values in the following table:\nAngle above or below the horizontal plane Intensity, l\n0° 1.00\n0° to 5° 0.90\n5° to 10° 0.80\n10° to 15° 0.70\n15° to 20° 0.50\n20° to 30° 0.30\n30° to 40° 0.10\n40° to 90° 0.05","path":["Title 14—Aeronautics and Space","CHAPTER I—FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION","SUBCHAPTER C—AIRCRAFT","PART 27—AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT","Subpart F—Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-14.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:24:20Z","sha256":"6b265cf493669162a6eafcdc67a8fa956f3c3af5d7f14012148739cbc64ad33b","source_id":"us-cfr","stale":true,"prev":"us/14-cfr-27.1391","next":"us/14-cfr-27.1395"},"notice":"GroundRules: Original legal text. Not legal advice."}