{"data":{"id":"us/24-cfr-3280.104","jurisdiction":"us","citation":"24 CFR 3280.104","heading":"Ceiling heights.","body":"(a) Every habitable room and bathroom shall have a minimum ceiling height of not less than 7 feet, 0 inches for a minimum of 50 percent of the room's floor area. The remaining area may have a ceiling with a minimum height of 5 feet, 0 inches. Minimum height under dropped ducts, beams, etc. shall be 6 feet, 4 inches.\n(b) Hallways and foyers shall have a minimum ceiling height of 6 feet, 6 inches.","path":["Title 24—Housing and Urban Development","Subtitle B—Regulations Relating to Housing and Urban Development","CHAPTER XX—OFFICE OF ASSISTANT SECRETARY FOR HOUSING—FEDERAL HOUSING COMMISSIONER, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT","PART 3280—MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS","Subpart B—Planning Considerations"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-24.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:24:55Z","sha256":"97217ab58ec4879013ca29169407cde472faed89428ef76da402960bf053e163","source_id":"us-cfr","stale":true,"prev":"us/24-cfr-3280.103","next":"us/24-cfr-3280.105"},"notice":"GroundRules: Original legal text. Not legal advice."}