{"data":{"id":"us/24-cfr-3285.405","jurisdiction":"us","citation":"24 CFR 3285.405","heading":"Severe wind zones.","body":"When any part of a home is installed within 1,500 feet of a coastline in Wind Zones II or III, the manufactured home must be designed for the increased requirements, as specified on the home's data plate (refer to § 3280.5(f) of this chapter) in accordance with acceptable engineering practice. Where site or other conditions prohibit the use of the manufacturer's instructions, a registered professional engineer or registered architect, in accordance with acceptable engineering practice, must design anchorage for the special wind conditions.","path":["Title 24—Housing and Urban Development","Subtitle B—Regulations Relating to Housing and Urban Development","CHAPTER XX—OFFICE OF ASSISTANT SECRETARY FOR HOUSING—FEDERAL HOUSING COMMISSIONER, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT","PART 3285—MODEL MANUFACTURED HOME INSTALLATION STANDARDS","Subpart E—Anchorage Against Wind"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-24.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:24:55Z","sha256":"c61ca51fcad2e4e71d864282ce105e6ff4bd1172851a9383cc1a676354407d69","source_id":"us-cfr","stale":true,"prev":"us/24-cfr-3285.404","next":"us/24-cfr-3285.406"},"notice":"GroundRules: Original legal text. Not legal advice."}