{"data":{"id":"us/30-cfr-250.510","jurisdiction":"us","citation":"30 CFR 250.510","heading":"Diesel engine air intakes.","body":"Diesel engine air intakes must be equipped with a device to shut down the diesel engine in the event of runaway. Diesel engines that are continuously attended must be equipped with either remote operated manual or automatic-shutdown devices. Diesel engines that are not continuously attended must be equipped with automatic-shutdown devices.","path":["Title 30—Mineral Resources","CHAPTER II—BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR","SUBCHAPTER B—OFFSHORE","PART 250—OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF","Subpart E—Oil and Gas Well-Completion Operations"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-30.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:24Z","sha256":"449add53c9288054be8bbf91d76abce604cc935e0cfb881168b7bd04d7b2c8a7","source_id":"us-cfr","stale":true,"prev":"us/30-cfr-250.509","next":"us/30-cfr-250.511"},"notice":"GroundRules: Original legal text. Not legal advice."}