{"data":{"id":"us/30-cfr-250.760","jurisdiction":"us","citation":"30 CFR 250.760","heading":"What are the snubbing requirements?","body":"(a) For snubbing operations, you must follow the applicable requirements of this subpart and have the following minimum BOP-system components:\n(1) One set of pipe rams hydraulically operated,\n(2) Two sets of stripper-type pipe rams hydraulically operated with spacer spool,\n(3) An inside BOP or a spring-loaded, back-pressure safety valve in the open position located on the rig floor, and\n(4) An essentially full-opening, work-string safety valve in the open position must be maintained on the rig floor at all times and a wrench to fit the work-string safety valve must be readily available.\n(5) Proper connections must be readily available for inserting valves in the work string.\n(b) Test the snubbing unit in accordance with § 250.737(a), (b), and (c).","path":["Title 30—Mineral Resources","CHAPTER II—BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR","SUBCHAPTER B—OFFSHORE","PART 250—OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF","Subpart G—Well Operations and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-30.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:24Z","sha256":"babf5323b6c95c3cb01c6cc966a417c5fe54c85452b6e7f5a5807847dd5c4fb6","source_id":"us-cfr","stale":true,"prev":"us/30-cfr-250.751","next":"us/30-cfr-250.800"},"notice":"GroundRules: Original legal text. Not legal advice."}