{"data":{"id":"us/30-cfr-57.12088","jurisdiction":"us","citation":"30 CFR 57.12088","heading":"Splicing trailing cables.","body":"No splice, except a vulcanized splice or its equivalent, shall be made in a trailing cable within 25 feet of the machine unless the machine is equipped with a cable reel or other power feed cable payout-retrieval system. However, a temporary splice may be made to move the equipment for repair.","path":["Title 30—Mineral Resources","CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","SUBCHAPTER K—METAL AND NONMETAL MINE SAFETY AND HEALTH","PART 57—SAFETY AND HEALTH STANDARDS—UNDERGROUND METAL AND NONMETAL MINES","Subpart K—Electricity"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-30.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:24Z","sha256":"12f66ec4c0bfa1f93921636600f320c430381ad3185009bfb525f1741c73031f","source_id":"us-cfr","stale":true,"prev":"us/30-cfr-57.12086","next":"us/30-cfr-57.13001"},"notice":"GroundRules: Original legal text. Not legal advice."}