{"data":{"id":"us/30-cfr-57.19025","jurisdiction":"us","citation":"30 CFR 57.19025","heading":"Load end attachments.","body":"(a) Wire rope shall be attached to the load by a method that develops at least 80 percent of the nominal strength of the rope.\n(b) Except for terminations where use of other materials is a design feature, zinc (spelter) shall be used for socketing wire ropes. Design feature means either the manufacturer's original design or a design approved by a registered professional engineer\n(c) Load end attachment methods using splices are prohibited.","path":["Title 30—Mineral Resources","CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","SUBCHAPTER K—METAL AND NONMETAL MINE SAFETY AND HEALTH","PART 57—SAFETY AND HEALTH STANDARDS—UNDERGROUND METAL AND NONMETAL MINES","Subpart R—Personnel Hoisting"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-30.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:24Z","sha256":"2c325d8c87230098080b6acc504cb1ad3a5aa3ad622e12548c0d523d50f9e2ad","source_id":"us-cfr","stale":true,"prev":"us/30-cfr-57.19024","next":"us/30-cfr-57.19026"},"notice":"GroundRules: Original legal text. Not legal advice."}