{"data":{"id":"us/30-cfr-57.6102","jurisdiction":"us","citation":"30 CFR 57.6102","heading":"Explosive material storage practices.","body":"(a) Explosive material shall be—\n(1) Stored in a manner to facilitate use of oldest stocks first;\n(2) Stored according to brand and grade in such a manner as to facilitate identification; and\n(3) Stacked in a stable manner but not more than 8 feet high.\n(b) Explosives and detonators shall be stored in closed nonconductive containers except that nonelectric detonating devices may be stored on nonconductive racks provided the case-insert instructions and the date-plant-shift code are maintained with the product.","path":["Title 30—Mineral Resources","CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","SUBCHAPTER K—METAL AND NONMETAL MINE SAFETY AND HEALTH","PART 57—SAFETY AND HEALTH STANDARDS—UNDERGROUND METAL AND NONMETAL MINES","Subpart E—Explosives"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-30.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:24Z","sha256":"7b40b4cd178bf5707c3e5b0cf6d4dc83770065321809cbfc6ea79a2ee02fc243","source_id":"us-cfr","stale":true,"prev":"us/30-cfr-57.6101","next":"us/30-cfr-57.6130"},"notice":"GroundRules: Original legal text. Not legal advice."}