{"data":{"id":"us/30-cfr-75.1403-6","jurisdiction":"us","citation":"30 CFR 75.1403-6","heading":"-6 Criteria—Self-propelled personnel carriers.","body":"(a) Each self-propelled personnel carrier should:\n(1) Be provided with an audible warning device;\n(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;\n(3) Be provided with reflectors on both ends and sides.\n(b) In addition, each track-mounted self-propelled personnel carrier should:\n(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;\n(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;\n(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;\n(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.","path":["Title 30—Mineral Resources","CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","Subpart O—Hoisting and Mantrips"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-30.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:24Z","sha256":"cf612068730063017d6eb5d3b6449b058028f235a39fa7b1ccb12456d1d54f4f","source_id":"us-cfr","stale":true,"prev":"us/30-cfr-75.1403-5","next":"us/30-cfr-75.1403-7"},"notice":"GroundRules: Original legal text. Not legal advice."}