{"data":{"id":"us/33-cfr-149.130","jurisdiction":"us","citation":"33 CFR 149.130","heading":"What are the requirements for the cargo transfer system alarm?","body":"(a) Each cargo transfer system must have an alarm to signal a malfunction or failure in the system.\n(b) The alarm must sound automatically in the control room and:\n(1) Be capable of being activated at the pumping platform complex;\n(2) Have a signal audible in all areas of the pumping platform complex, except in areas under paragraph (b)(3) of this section;\n(3) Have a high intensity flashing light in areas of high ambient noise levels where hearing protection is required under § 150.615 of this chapter; and\n(4) Be distinguishable from the general alarm.\n(c) Tankers calling on unmanned deepwater ports must be equipped with a transfer system alarm described in this section.","path":["Title 33—Navigation and Navigable Waters","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER NN—DEEPWATER PORTS","PART 149—DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT","Subpart B—Pollution Prevention Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-33.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:35Z","sha256":"0ffbfbcef141ab5e4993d63ba5252e84a37303e9f294a032d048b45e673d5afd","source_id":"us-cfr","stale":true,"prev":"us/33-cfr-149.125","next":"us/33-cfr-149.135"},"notice":"GroundRules: Original legal text. Not legal advice."}