{"data":{"id":"us/33-cfr-159.115","jurisdiction":"us","citation":"33 CFR 159.115","heading":"Temperature range test.","body":"(a) The device must be held at a temperature of 60 °C or higher for a period of 16 hours.\n(b) The device must be held at a temperature of −40 °C or less for a period of 16 hours following winterization in accordance with manufacturers' instructions.","path":["Title 33—Navigation and Navigable Waters","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—POLLUTION","PART 159—MARINE SANITATION DEVICES","Subpart C—Design, Construction, and Testing"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-33.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:35Z","sha256":"e215c26fee9ccb717ecf551e70a435babf771457edaeabcc09ed7f099f71553f","source_id":"us-cfr","stale":true,"prev":"us/33-cfr-159.111","next":"us/33-cfr-159.117"},"notice":"GroundRules: Original legal text. Not legal advice."}