{"data":{"id":"us/33-cfr-183.580","jurisdiction":"us","citation":"33 CFR 183.580","heading":"Static pressure test for fuel tanks.","body":"A fuel tank is tested by performing the following procedures in the following order:\n(a) Fill the tank with air or inert gas to the pressure marked on the tank label under § 183.514(b)(5).\n(b) Examine each tank fitting and seam for leaks using a leak detection method other than the pressure drop method.","path":["Title 33—Navigation and Navigable Waters","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER S—BOATING SAFETY","PART 183—BOATS AND ASSOCIATED EQUIPMENT","Subpart J—Fuel Systems"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-33.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:25:35Z","sha256":"e6e9e742e226f58e4be5c5272bde32b60f516e4a5eb7c0c89780a549c7b2b4cd","source_id":"us-cfr","stale":true,"prev":"us/33-cfr-183.572","next":"us/33-cfr-183.584"},"notice":"GroundRules: Original legal text. Not legal advice."}