{"data":{"id":"us/40-cfr-410.13","jurisdiction":"us","citation":"40 CFR 410.13","heading":"Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).","body":"(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):\nPollutant or pollutant property BAT limitations\nMaximum for any 1 day Average of daily values for 30 consecutive days\nKg/kkg (or pounds per 1,000 lb) of wool\nCOD 138.0 69.0\nSulfide 0.20 0.10\nPhenols 0.10 0.05\nTotal chromium 0.10 0.05\n(b) Additional allocations equal to the effluent limitations established in paragraph (a) of this section are allowed any existing point source subject to such effluent limitations that scours wool through “commission scouring” as defined in § 410.11.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 410—TEXTILE MILLS POINT SOURCE CATEGORY","Subpart A—Wool Scouring Subcategory"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"92cb15245d04ade5bc7012c793be1aeace88a546b38a170b69f0bfe7dacf0d33","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-410.12","next":"us/40-cfr-410.14"},"notice":"GroundRules: Original legal text. Not legal advice."}