{"data":{"id":"us/40-cfr-417.32","jurisdiction":"us","citation":"40 CFR 417.32","heading":"Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.","body":"Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):\nEffluent characteristic Effluent limitations\nMaximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—\nMetric units (kilograms per 1,000 kg of anhydrous product)\nBOD5 0.03 0.01\nCOD 0.15 .05\nTSS 0.06 .02\nOil and grease 0.03 .01\npH (1) (1)\nEnglish units (pounds per 1,000 lb of anhydrous product)\nBOD5 0.03 0.01\nCOD 0.15 .05\nTSS 0.06 .02\nOil and grease 0.03 .01\npH (1) (1)\n1 Within the range 6.0 to 9.0.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 417—SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY","Subpart C—Soap Manufacturing by Fatty Acid Neutralization Subcategory"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"666b5fd3ee268f7d755a8f2a326b4c5d0c07701099ff5712a87b353fde798e49","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-417.31","next":"us/40-cfr-417.33"},"notice":"GroundRules: Original legal text. Not legal advice."}