{"data":{"id":"us/40-cfr-418.15","jurisdiction":"us","citation":"40 CFR 418.15","heading":"Standards of performance for new sources.","body":"The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart:\n(a) Subject to the provision of paragraphs (b) and (c) of this section, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available demonstrated control technology: There shall be no discharge of process wastewater pollutants to navigable waters.\n(b) Process wastewater pollutants from a calcium sulfate storage pile runoff facility operated separately or in combination with a water recirculation system designed, constructed and operated to maintain a surge capacity equal to the runoff from the 25-year, 24-hour rainfall event may be discharged, after treatment to the standards set forth in paragraph (c) of this section, whenever chronic or catastrophic precipitation events cause the water level to rise into the surge capacity. Process wastewater must be treated and discharged whenever the water level equals or exceeds the midpoint of the surge capacity.\n(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:\nEffluent characteristic Effluent limitations (mg/l)\nMaximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—\nTotal phosphorus (as P) 105 35\nFluoride 75 25\nTSS 150 50\nThe total suspended solid limitation set forth in this paragraph shall be waived for process wastewater from a calcium sulfate storage pile runoff facility, operated separately or in combination with a water recirculation system, which is chemically treated and then clarified or settled to meet the other pollutant limitations set forth in this paragraph.\n(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:\nEffluent characteristic Effluent limitations (mg/l)\nMaximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—\nTotal phosphorus (as P) 105 35\nFluoride 75 25","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","Subpart A—Phosphate Subcategory"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"9671e0f94aba8e36efb154221125637e07328e6b0581e4085a1a63b8503569ca","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-418.14","next":"us/40-cfr-418.16"},"notice":"GroundRules: Original legal text. Not legal advice."}
