{"data":{"id":"us/40-cfr-432.125","jurisdiction":"us","citation":"40 CFR 432.125","heading":"New source performance standards (NSPS).","body":"Any source that is a new source subject to this subpart must achieve the following performance standards:\n(a) Facilities that further process no more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:\nPerformance Standards\n[NSPS]\nRegulated parameter Maximum daily 1 Maximum monthly avg. 1\nAmmonia (as N) 8.0 4.0\nBOD5 26 16\nFecal Coliform (2) (3)\nO\u0026G (as HEM) 14 8.0\nTSS 30 20\n1 mg/L (ppm).\n2 Maximum of 400 MPN or CFU per 100 mL at any time.\n3 No maximum monthly average limitation.\n(b) Facilities that further process more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:\nEffluent Limitations\n[NSPS]\nRegulated parameter Maximum daily 1 Maximum monthly avg. 1\nAmmonia (as N) 8.0 4.0\nBOD5 26 16\nFecal Coliform (2) (3)\nO\u0026G (as HEM) 14 8.0\nTSS 30 20\nTotal Nitrogen 147 103\n1 mg/L (ppm).\n2 Maximum of 400 MPN or CFU per 100 mL at any time.\n3 No maximum monthly average limitation.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 432—MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY","Subpart L—Poultry Further Processing"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"faa584bb6962593b5460a35b0fefc630edf1b9b440b3838f68fd089be9713ee1","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-432.124","next":"us/40-cfr-432.126"},"notice":"GroundRules: Original legal text. Not legal advice."}