{"data":{"id":"us/40-cfr-432.52","jurisdiction":"us","citation":"40 CFR 432.52","heading":"Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).","body":"Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:\nEffluent Limitations\n[BPT]\nRegulated parameter Maximum daily 1 Maximum monthly avg. 1\nBOD5 2.0 1.0\nFecal Coliform (2) (2)\nO\u0026G 3 1.0 0.5\nTSS 2.4 1.2\n1 Pounds per 1000 lbs (or g/kg) of finished product.\n2 No limitation.\n3 May be measured as hexane extractable material (HEM).","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 432—MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY","Subpart E—Small Processors"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"09d4fbc7da51764b5cf6d9f6df4e4c0de1cab160e7bff243ceeedf882c213b71","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-432.51","next":"us/40-cfr-432.54"},"notice":"GroundRules: Original legal text. Not legal advice."}