{"data":{"id":"us/40-cfr-445.11","jurisdiction":"us","citation":"40 CFR 445.11","heading":"Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).","body":"Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT:\nEffluent Limitations\nRegulated parameter Maximum daily 1 Maximum monthly avg. 1\nBOD5 220 56\nTSS 88 27\nAmmonia (as N) 10 4.9\nα-Terpineol 0.042 0.019\nAniline 0.024 0.015\nBenzoic acid 0.119 0.073\nNaphthalene 0.059 0.022\np-Cresol 0.024 0.015\nPhenol 0.048 0.029\nPyridine 0.072 0.025\nArsenic 1.1 0.54\nChromium 1.1 0.46\nZinc 0.535 0.296\npH (2) (2)\n1 Milligrams per liter (mg/L, ppm).\n2 Within the range 6 to 9.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 445—LANDFILLS POINT SOURCE CATEGORY","Subpart A—RCRA Subtitle C Hazardous Waste Landfill"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"37a29bff2ea101bd68d23366e838339313da38988b256a704eb05008f17fa7b3","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-445.10","next":"us/40-cfr-445.12"},"notice":"GroundRules: Original legal text. Not legal advice."}