{"data":{"id":"us/40-cfr-469.15","jurisdiction":"us","citation":"40 CFR 469.15","heading":"Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).","body":"Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):\nSubpart A—Semiconductor BAT Effluent Limitations\nPollutant or pollutant property Maximum for any 1 day Average of daily values for 30 consecutive days\nMilligrams per liter (mg/l)\nTTO 1 1.37 (2)\nFluoride (T) 32.0 17.4\n1 Total toxic organics.\n2 Not applicable.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS","PART 469—ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY","Subpart A—Semiconductor Subcategory"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"0c52fb60e0b6327b5d950c25a34075c7e3628c97b6ac3abb89779dc754950b1c","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-469.14","next":"us/40-cfr-469.16"},"notice":"GroundRules: Original legal text. Not legal advice."}