{"data":{"id":"us/40-cfr-60.282","jurisdiction":"us","citation":"40 CFR 60.282","heading":"Standard for particulate matter.","body":"(a) On and after the date on which the performance test required to be conducted by § 60.8 is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere:\n(1) From any recovery furnace any gases which:\n(i) Contain particulate matter in excess of 0.10 g/dscm (0.044 gr/dscf) corrected to 8 percent oxygen.\n(ii) Exhibit 35 percent opacity or greater.\n(2) From any smelt dissolving tank any gases which contain particulate matter in excess of 0.1 g/kg black liquor solids (dry weight)[0.2 lb/ton black liquor solids (dry weight)].\n(3) From any lime kiln any gases which contain particulate matter in excess of:\n(i) 0.15 g/dscm (0.066 gr/dscf) corrected to 10 percent oxygen, when gaseous fossil fuel is burned.\n(ii) 0.30 g/dscm (0.13 gr/dscf) corrected to 10 percent oxygen, when liquid fossil fuel is burned.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES","Subpart BB—Standards of Performance for Kraft Pulp Mills"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"5c5017de313d7c7bd1d4a7eb279507f11fd10178a9f8315d048e2855a0a80de1","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-60.281","next":"us/40-cfr-60.283"},"notice":"GroundRules: Original legal text. Not legal advice."}