{"data":{"id":"us/40-cfr-60.5950","jurisdiction":"us","citation":"40 CFR 60.5950","heading":"What additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system?","body":"(a) Use the required span values and applicable performance specifications in Table 3 to Subpart VVVV.\n(b) For continuous emission monitoring systems measuring carbon monoxide, if your municipal waste combustor is subject to the 100 parts per million dry volume carbon monoxide standard, the relative accuracy criterion of 5 parts per million dry volume is calculated as the absolute value of the mean difference between the reference method and continuous emission monitoring systems.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES","Subpart VVVV—Standards of Performance for Large Municipal Waste Combustors"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"488acf8eca2e64f0b9332fdc2da5cfa4a0a8ca32c8f656f227a340722f87c572","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-60.5945","next":"us/40-cfr-60.5955"},"notice":"GroundRules: Original legal text. Not legal advice."}