{"data":{"id":"us/40-cfr-60.6505","jurisdiction":"us","citation":"40 CFR 60.6505","heading":"What additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system?","body":"(a) Use the required span values and applicable performance specifications in Table 4 to Subpart WWWW.\n(b) For continuous emission monitoring systems measuring carbon monoxide, if your municipal waste combustor is subject to the 100 parts per million dry volume carbon monoxide standard, the relative accuracy criterion of 5 parts per million dry volume is calculated as the absolute value of the mean difference between the reference method and continuous emission monitoring systems.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES","Subpart WWWW—Emission Guidelines and Compliance Times for Large Municipal Waste Combustors Constructed on or Before January 23, 2024"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"3b04847d947a246f563e7738f78683c942d1424eaf903d21e996ebdfc866a33d","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-60.6500","next":"us/40-cfr-60.6510"},"notice":"GroundRules: Original legal text. Not legal advice."}