{"data":{"id":"us/40-cfr-63.3092","jurisdiction":"us","citation":"40 CFR 63.3092","heading":"How must I control emissions from my electrodeposition primer system if I want to comply with the combined primer-surfacer, topcoat, final repair, glass bonding primer, and glass bonding adhesive emission limit?","body":"If your electrodeposition primer system meets the requirements of either paragraph (a) or (b) of this section, you may choose to comply with the emission limits of § 63.3090(b) or § 63.3091(b) instead of the emission limits of § 63.3090(a) or § 63.3091(a).\n(a) Each individual material added to the electrodeposition primer system contains no more than:\n(1) 1.0 percent by weight of any organic HAP; and\n(b) Emissions from all bake ovens used to cure electrodeposition primers must be captured and ducted to a control device having a destruction or removal efficiency of at least 95 percent.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES","Subpart IIII—National Emission Standards for Hazardous Air Pollutants: Surface Coating of Automobiles and Light-Duty Trucks"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"e6725b06cd8803ca68e8058dcf680673950ce5a97387cce2cea0862732fefef7","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-63.3091","next":"us/40-cfr-63.3093"},"notice":"GroundRules: Original legal text. Not legal advice."}