{"data":{"id":"us/40-cfr-appendix-d-to-part-61","jurisdiction":"us","citation":"40 CFR Appendix D to Part 61","heading":"Appendix D to Part 61—Methods for Estimating Radionuclide Emissions","body":"1. Purpose and Background\nFacility owners or operators may estimate radionuclide emissions to the atmosphere for dose calculations instead of measuring emissions. Particulate emissions from mill tailings piles should be estimated using the procedures listed in reference re #2. All other emissions may be estimated by using the “Procedures” listed below, or using the method described in reference #1.\n2. Procedure\nTo estimate emissions to the atmosphere:\n(a) Determine the amount (in curies) used at facilities for the period under consideration. Radioactive materials in sealed packages that remain unopened, and have not leaked during the assessment period should not be included in the calculation.\n(b) Multiply the amount used by the following factors which depend on the physical state of the radionuclide. They are:\n(i) 1 for gases;\n(ii) 10−3 for liquids or particulate solids; and\n(iii) 10−6 for solids.\nIf any nuclide is heated to a temperature of 100 degrees Celsius or more, boils at a temperature of 100 degrees Celsius or less, or is intentionally dispersed into the environment, it must be considered to be a gas.\n(c) If a control device is installed between the place of use and the point of release, multiply emissions from (b) by an adjustment factor. These are presented in Table 1.\nTable 1—Adjustment to Emission Factors for Effluent Controls\nControls Types of radionuclides controlled Adjustment factor to emissions Comments and conditions\nHEPA filters Particulates 0.01 Not applicable to gaseous radionuclides; periodic testing is prudent to ensure high removal efficiency.\nFabric filter Particulates 0.1 Monitoring would be prudent to guard against tears in filter.\nSintered metal Particulates 1 Insufficient data to make recommendation.\nActivated carbon filters Iodine gas 0.1 Efficiency is time dependent; monitoring is necessary to ensure effectiveness.\nDouglas bags: Held one week or longer for decay Xenon 0.5/wk Based on xenon half-life of 5.3 days;\nDouglas bags: Released within one week Xenon 1 Provides no reduction of exposure to general public.\nVenturi scrubbers Particulates Gases 0.05 1 Although venturis may remove gases, variability in gaseous removal efficiency dictates adjustment factor for particulates only.\nPacked bed scrubbers Gases 0.1 Not applicable to particulates.\nElectrostatic precipitators Particulates 0.05 Not applicable for gaseous radionuclides\nXenon traps Xenon 0.1 Efficiency is time dependent; monitoring is necessary to ensure effectiveness.\nFume hoods All 1 Provides no reduction to general public exposures.\nVent stacks All 1 Generally provides no reduction of exposure to general public.\nReferences\n(1) Environmental Protection Agency, “A Guide for Determining Compliance with the Clean Air Act Standards for Radionuclides Emissions from NRC-Licensed and Non-DOE Federal Facilities”, EPA 520/1-89-002, January 1989.\n(2) Nuclear Regulatory Commission, “Methods for Estimating Radioactive and Toxic Airborne Source Terms for Uranium Milling Operations”, U.S. Nuclear Regulatory Commission Regulatory Guide 3.59, March 1987.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 61—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"3331148761c31dd6eabdd407dd44a77777d4f6cac10d0a0de3e06cead44bbe1a","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-appendix-c-to-part-61","next":"us/40-cfr-appendix-e-to-part-61"},"notice":"GroundRules: Original legal text. Not legal advice."}