{"data":{"id":"us/40-cfr-table-1-to-subpart-nnna-of-part-60","jurisdiction":"us","citation":"40 CFR Table 1 to Subpart NNNa of Part 60","heading":"Table 1 to Subpart NNNa of Part 60—Emission Limits and Standards for Vent Streams","body":"For each . . . You must . . .\n1. Vent stream a. Reduce emissions of TOC (minus methane and ethane) by 98 weight-percent, or to a TOC (minus methane and ethane) concentration of 20 ppmv on a dry basis corrected to 3 percent oxygen by venting emissions through a closed vent system to any combination of non-flare control devices and/or recovery system and meet the requirements specified in § 60.663a and § 60.670a; or\nb. Reduce emissions of TOC (minus methane and ethane) by venting emissions through a closed vent system to a flare and meet the requirements specified in § 60.669a and § 60.670a.","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES","Subpart NNNa—Standards of Performance for Volatile Organic Compound (VOC) Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Distillation Operations for Which Construction, Reconstruction, or Modification Commenced After April 25, 2023"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"95c883573a30dce458395a13ce28e72914dca70bfb23d574d7592b0369da0058","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-60.670a","next":"us/40-cfr-table-2-to-subpart-nnna-of-part-60"},"notice":"GroundRules: Original legal text. Not legal advice."}