{"data":{"id":"us/40-cfr-table-2-to-subpart-lll-of-part-62","jurisdiction":"us","citation":"40 CFR Table 2 to Subpart LLL of Part 62","heading":"Table 2 to Subpart LLL of Part 62—Emission Limits and Standards for Existing Fluidized Bed Sewage Sludge Incineration Units","body":"For the air pollutant You must meet this emission limit 1 Using these averaging methods and minimum sampling volumes or durations And determining compliance using this method\nParticulate matter 18 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters sample per run) Performance test (Method 5 at 40 CFR part 60, appendix A-3; Method 26A or Method 29 at 40 CFR part 60, appendix A-8).\nHydrogen chloride 0.51 parts per million by dry volume 3-run average (Collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 26A at 40 CFR part 60, appendix A-8).\nCarbon monoxide 64 parts per million by dry volume 3-run average (collect sample for a minimum duration of one hour per run) Performance test (Method 10, 10A, or 10B at 40 CFR part 60, appendix A-4).\nDioxins/furans (total mass basis); or 1.2 nanograms per dry standard cubic meter (total mass basis); or 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 23 at 40 CFR part 60, appendix A-7).\nDioxins/furans (toxic equivalency basis) 2 0.10 nanograms per dry standard cubic meter (toxic equivalency basis)\nMercury 0.037 milligrams per dry standard cubic meter 3-run average (For Method 29 and ASTM D6784-02 (Reapproved 2008) 3 , collect a minimum volume of 1 dry standard cubic meters per run. For Method 30B, collect a minimum sample as specified in Method 30B at 40 CFR part 60, appendix A-8) Performance test (Method 29 at 40 CFR part 60, appendix A-8; Method 30B at 40 CFR part 60, appendix A-8; or ASTM D6784-02 (Reapproved 2008).3 5\nOxides of nitrogen 150 parts per million by dry volume 3-run average (Collect sample for a minimum duration of one hour per run) Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4).\nSulfur dioxide 15 parts per million by dry volume 3-run average (For Method 6, collect a minimum volume of 60 liters per run. For Method 6C, collect sample for a minimum duration of one hour per run) Performance test (Method 6 or 6C at 40 CFR part 40, appendix A-4; or ANSI/ASME PTC-19.10-1981.3 4\nCadmium 0.0016 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use GFAAS or ICP/MS for the analytical finish.\nLead 0.0074 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters sample per run) Performance test (Method 29 at 40 CFR part 60, appendix A-8. Use GFAAS or ICP/MS for the analytical finish.\nFugitive emissions from ash handling Visible emissions of combustion ash from an ash conveying system (including conveyor transfer points) for no more than 5 percent of any compliance test hourly observation period Three 1-hour observation periods Visible emission test (Method 22 at 40 CFR part 60, appendix A-7).\n1 All emission limits are measured at 7-percent oxygen, dry basis at standard conditions.\n2 You have the option to comply with either the dioxin/furan emission limit on a total mass basis or the dioxin/furan emission limit on a toxic equivalency basis.\n3 The Director of the Federal Register approves these incorporations by reference in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. You may inspect these standards at U.S. Environmental Protection Agency, 1200 Pennsylvania Avenue NW., Washington, DC 20460, (202) 272-0167, http://www.epa.gov. You may also inspect a copy at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: {HYPERLINK “http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html”}.\n4 ANSI/ASME PTC 19.10-1981, Flue and Exhaust Gas Analyses [Part 10, Instruments and Apparatus]. American Society of Mechanical Engineers (ASME), Three Park Avenue, New York, NY 10016-5990 (Phone: 1-800-843-2763; Web site: https://www.asme.org/).\n5 ASTM D6784-02 (Reapproved 2008) Standard Test Method for Elemental, Oxidized, Particle-Bound and Total Mercury in Flue Gas Generated from Coal-Fired Stationary Sources (Ontario Hydro Method), [approved April 1, 2008]. ASTM International, 100 Barr Harbor Drive, Post Office Box C700, West Conshohocken, PA 19428-2959; ProQuest, 300 North Zeeb Road, Ann Arbor, MI 48106 (Phone: 1-877-909-2786; Web site: http://www.astm.org/).","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 62—APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS","Subpart LLL—Federal Plan Requirements for Sewage Sludge Incineration Units Constructed on or Before October 14, 2010"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"9e6fdb6564a34e189bf2a084aed7bccb6fe1fad1be0d3d8141abc32200f543a8","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-table-1-to-subpart-lll-of-part-62","next":"us/40-cfr-table-3-to-subpart-lll-of-part-62"},"notice":"GroundRules: Original legal text. Not legal advice."}