{"data":{"id":"us/40-cfr-table-3-to-subpart-d-of-part-65","jurisdiction":"us","citation":"40 CFR Table 3 to Subpart D of Part 65","heading":"Table 3 to Subpart D of Part 65—TRE Parameters for HON Referencing Subparts a","body":"Existing or new? Halogenated vent stream? Values of terms for TRE equation: TRE = A * [ B + C + D + E + F ]\nA B C D E F Equation number\nExisting Yes 1/EHAP 3.995 0.05200Q 0 −0.001769H 0.0009700ETOC 33\nNo 1/EHAP 1.935 0.3660Q 0 −0.007687H −0.000733ETOC 34\n1/EHAP 1.492 0.06267Q 0 0.03177H −0.001159ETOC 35\n1/EHAP 2.519 0.01183Q 0 0.01300H 0.04790ETOC 36\nNew Yes 1/EHAP 1.0895 0.01417Q 0 −0.000482H 0.0002645ETOC 37\nNo 1/EHAP 0.5276 0.0998Q 0 −0.002096H −0.0002000ETOC 38\n1/EHAP 0.4068 0.0171Q 0 0.008664H −0.000316ETOC 39\n1/EHAP 0.6868 0.00321Q 0 0.003546H 0.01306ETOC 40\na Use according to procedures outlined in § 65.64(h).","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 65—CONSOLIDATED FEDERAL AIR RULE","Subpart D—Process Vents"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"dc611bad521d038222f8b1f202556b7be29adaf1fd4f2c9d024f1273c4b41f1b","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-table-2-to-subpart-d-of-part-65","next":"us/40-cfr-65.80"},"notice":"GroundRules: Original legal text. Not legal advice."}