{"data":{"id":"us/40-cfr-table-3-to-subpart-ec-of-part-60","jurisdiction":"us","citation":"40 CFR Table 3 to Subpart Ec of Part 60","heading":"Table 3 to Subpart Ec of Part 60—Operating Parameters To Be Monitored and Minimum Measurement and Recording Frequencies","body":"Operating parameters to be monitored Minimum frequency Control system\nData measurement Data recording Dry scrubber followed by fabric filter Wet scrubber Dry scrubber followed by fabric filter and wet scrubber\nMaximum operating parameters:\nMaximum charge rate Continuous 1 × hour ✔ ✔ ✔\nMaximum fabric filter inlet temperature Continuous 1 × minute ✔ ✔\nMaximum flue gas temperature Continuous 1 × minute ✔ ✔\nMinimum operating parameters:\nMinimum secondary chamber temperature Continuous 1 × minute ✔ ✔ ✔\nMinimum dioxin/furan sorbent flow rate Hourly 1 × hour ✔ ✔\nMinimum HCI sorbent flow rate Hourly 1 × hour ✔ ✔\nMinimum mercury (Hg) sorbent flow rate Hourly 1 × hour ✔ ✔\nMinimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber Continuous 1 × minute ✔ ✔\nMinimum scrubber liquor flow rate Continuous 1 × minute ✔ ✔\nMinimum scrubber liquor pH Continuous 1 × minute ✔ ✔","path":["Title 40—Protection of Environment","CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY","SUBCHAPTER C—AIR PROGRAMS","PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES","Subpart Ec—Standards of Performance for New Stationary Sources: Hospital/Medical/Infectious Waste Incinerators"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-40.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:04Z","sha256":"065cbb5c8f05db18acf1d52c427820bf4ce079c39f79a7ac4a1bf9c34de00565","source_id":"us-cfr","stale":true,"prev":"us/40-cfr-table-2-to-subpart-ec-of-part-60","next":"us/40-cfr-60.60"},"notice":"GroundRules: Original legal text. Not legal advice."}