{"data":{"id":"us/43-cfr-3175.111","jurisdiction":"us","citation":"43 CFR 3175.111","heading":"General sampling requirements.","body":"(a) Samples must be taken by one of the following methods:\n(1) Spot sampling under §§ 3175.113 through 3175.115;\n(2) Flow-proportional composite sampling under § 3175.116; or\n(3) On-line gas chromatograph under § 3175.117.\n(b) At all times during the sampling process, the minimum temperature of all gas sampling components must be the lesser of:\n(1) The flowing temperature of the gas measured at the time of sampling; or\n(2) 30 °F above the calculated hydrocarbon dew point of the gas.","path":["Title 43—Public Lands: Interior","Subtitle B—Regulations Relating to Public Lands","CHAPTER II—BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR","SUBCHAPTER C—MINERALS MANAGEMENT (3000)","PART 3170—ONSHORE OIL AND GAS PRODUCTION","Subpart 3175—Measurement of Gas"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-43.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:15Z","sha256":"9d2222e40d1e0894459057f912096817463a74e6148e51ba53b9032e55acdace","source_id":"us-cfr","stale":true,"prev":"us/43-cfr-3175.110","next":"us/43-cfr-3175.112"},"notice":"GroundRules: Original legal text. Not legal advice."}