{"data":{"id":"us/46-cfr-111.05-23","jurisdiction":"us","citation":"46 CFR 111.05-23","heading":"-23 Location of ground indicators.","body":"Ground indicators must:\n(a) Be at the vessel's ship's service generator distribution switchboard for the normal power, normal lighting, and emergency lighting systems;\n(b) Be at the propulsion switchboard for propulsion systems; and\n(c) Be readily accessible.\n(d) Be provided (at the distribution switchboard or at another location, such as a centralized monitoring position for the circuit affected) for each feeder circuit that is isolated from the main source by a transformer or other device.\nNote to paragraph (d):\nAn alarm contact or indicating device returned to the main switchboard via a control cable, that allows the detecting equipment to remain near the transformer or other isolating device for local troubleshooting, is allowed.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.05—Equipment Ground, Ground Detection, and Grounded Systems"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"36afcc46caed490826bcc7527806a2c4b267fc4b735d862e62d26f426dc770c5","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.05-21","next":"us/46-cfr-111.05-25"},"notice":"GroundRules: Original legal text. Not legal advice."}