{"data":{"id":"us/46-cfr-111.103-7","jurisdiction":"us","citation":"46 CFR 111.103-7","heading":"-7 Ventilation stop stations.","body":"Each power ventilation system stop station must:\n(a) Be protected by an enclosure with a glass-paneled door on the front;\n(b) Be marked, “In Case of Fire Break Glass and Operate Switch to Stop Ventilation;”\n(c) Have the “stop” position of the switch clearly identified;\n(d) Have a nameplate that identifies the system controlled; and\n(e) Be arranged so that damage to the switch or cable automatically stops the equipment controlled.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.103—Remote Stopping Systems"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"9f6f7eaa358289b7dba0cf2122aba4ea1e76017a4e828377104ccca092880254","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.103-3","next":"us/46-cfr-111.103-9"},"notice":"GroundRules: Original legal text. Not legal advice."}