{"data":{"id":"us/46-cfr-111.105-29","jurisdiction":"us","citation":"46 CFR 111.105-29","heading":"-29 Combustible liquid cargo carriers.","body":"(a) Each vessel that carries combustible liquid cargo with a closed-cup flashpoint of 60 degrees C (140 degrees F) or higher must have:\n(1) Only intrinsically safe electric systems in cargo tanks; and\n(2) No storage battery in any cargo handling room.\n(b) If a submerged cargo pump motor is in a cargo tank, it must meet the requirements of § 111.105-31(d).\n(c) Where the cargo is heated to within 15 °C of its flashpoint, the cargo pumproom must meet the requirements of § 111.105-31(f) and the weather locations must meet § 111.105-31(l).","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.105—Hazardous Locations"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"f43828d2d182bef6d2499cf603be6e8ceed3447934ee32bcbc92c7f58d0b5872","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.105-28","next":"us/46-cfr-111.105-31"},"notice":"GroundRules: Original legal text. Not legal advice."}