{"data":{"id":"us/46-cfr-111.106-11","jurisdiction":"us","citation":"46 CFR 111.106-11","heading":"-11 Classification of storage and handling locations of heated combustible liquid cargoes.","body":"(a) This section applies to locations surrounding the storage and handling of combustible liquid cargoes with closed-cup flashpoints exceeding 60 °C (140 °F).\n(b) The interiors of independent storage tanks and integral tanks containing cargoes with closed-cup flashpoints of 60 °C (140 °F) or higher and heated to within 15 °C of their flashpoint are considered Class I Special Division 1 (Zone 0). The hazardous locations in § 111.106-9 of this subpart apply.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.106—Hazardous Locations on OSVs"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"616e205c4c5975109d1b7575d93cfabc441f7c1a39ef7836b98522338b4322b1","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.106-9","next":"us/46-cfr-111.106-13"},"notice":"GroundRules: Original legal text. Not legal advice."}